What temperature?


20 degrees centigrade is the standard temperature that film development should be carried out at. It is also important that this temperature be maintained throughout the process. You may use a higher or lower temperature which will shorten or lengthen the development time. There is a risk that the negatives may not be fully developed; you should wherever possible follow the instructions as to time and temperature unless an alternative has been suggested by those instructions. With experience you will know what temperature and time combinations give good results. I personally always develop my film at 20 degrees C unless a higher or lower temperature is recommended.

Friday, 9 December 2011

Farmers reducer.


This is a follow on from my last post on reduction.

Over developed or over exposed negatives may need to be reduced to make them a better printing prospect. This is achieved with chemicals that strip silver from the final image. Like developing, reducing a negative requires practice so you get an idea of how much to take away. It is best carried out in a place that is well ventilated with diffused light so you can see the process at work. It is a good idea to pre-soak the film it will allow you more control by slowing the process down. With experience you will get to know at what point to remove the negative. The chemicals do not stop working instantaneously. Because you can repeat this procedure it is better to reduce the negative in small steps so as not to over do it.

Reducers can be supplied ready mixed or you can mix your own. The formula that follows is a proportional reducer for overdeveloped negatives:

Stock Solution A

  • Potassium Ferricyanide 7.5 grams.
  • Water 1 litre.

Stock Solution B

  • Sodium thiosulphate (Hypo crystals) 200 grams.
  • Water 1 litre.

Notes: Ferricyanide has good keeping qualitys if kept out of strong sun light. Once you have mixed the chemicals you should use immediately. If you are using a stepped method of reduction do not contaminate solution A with Solution B as it will stop working. Working temperature of 20 degrees. You can place a dry negative in solution A but will need to watch the process carefully for between 1-4 minutes then transfer to solution B for about 5 minutes.

Potassium ferricyanide is a poison. Avoid contact with your skin and do not breathe the fumes.