Pages

Wednesday, 22 December 2021

Finding the edges of Eukobrom AC will hurt your pocket.

One open ,One untouched.
I have some good and bad news concerning Tetenal's Eukobrom AC. I have been pushing the developer to find it's limits. Without knowing where the edges are you cannot be sure that you are getting the optimum usage.


The good news is that two litres of diluted developer at 1 to 9 stored in a slot processor will remain usable for up to six weeks. Obviously this will vary depending on your circumstances. Also as the developer gets older the solution becomes more brown. Along with this it imparts some of this colour to the photograph by producing a subtle chocolate brown warmth in this case with Kentmere select RC gloss. A paper I have been using alot.


Used and depleted
The bad news is, while I have been involved in seeing how long a working solution will last, I forgot to mark the stock bottle with an 'opened on date'!. As a result 800 mls of unused developer has been thrown away. The first time I have had to do this ever! 

    
 I discovered this 'error' at the start of a printing   session. The existing developer was tested for   usability and found to be no longer viable. So I   made up a new batch to find that this was also   depleted. I was suspicious that the open bottle   was off by the colour but made up a new batch   anyway. In the past with other traditional   developers the colour does not always indicate   that it is exhausted. It took time to find out for   sure as the new developer was producing a very   soft test image without any contrast. I was using Kentmere paper, not known for being on the soft side and very quick to produce an image when placed in the developer, seconds in fact. In this case it still was not right after two minutes. After several attempts it was dumped. Not impressed to say the least.


Continence from open
bottle


Test Prints from open bottle of Eukobrom AC 


Not to worry I had a new unopened bottle. However on pouring the new bottle into the measuring jug this was brown in colour as well. Not the slight orange colour I was expecting. Now I was angry. I made up a batch anyway and to my surprise I was met with a well developed test image. Fully toned, great!

It took over an hour to get to this point what with one thing and another. My temper mellowed as each successive photograph left the developer fully toned.


Developer from fresh
bottle
Developer from
fresh bottle.























Test print in fresh developer..



Will I use the developer again? I still have the best part of a litre left from a dodgy opened bottle that has an 'opened on date'. As long as the contents are viable I will use it again. As to re stocking it? Not sure? It is just as well I keep some of my old friends in stock.

I did email Tetenal a long time ago to find out if they had any suggestions as to why this should be the case but have had no answer, I can share with you at the point of writing there is still no answer on posting.  



Printed on Kentmere RC gloss paper developed in Tetenal Eukobrom AC

This post was first published in 2017 there has not been any response from Tetenal on my concerns to this date.

Tuesday, 21 December 2021

Trouble in the darkroom


My darkroom is a very personal space, the only acknowledgement to it being standard is the separation of wet and dry working areas. It is just big enough for one person to work in comfortable. A bit of a glorified closet really! which has meant I have had to find ways of making the space work hard to meet the needs of both wet-and dry sides working areas.



One of the things I have had to do is to put the 12 x16 paper processor under the work top on a pull out shelf. It was done originally to save space but has proved to be inspired in a way I had not foreseen. Being able to look down on the print process has made it a more relaxed way to work. Keeping the work top clear for other wet side needs has not worked so well, the top is being dominated by the tray I use to put the tube covers that keep the chemicals fresh in the slot processor. It was a large tray so that the tops could be spaced far enough apart to stop cross contamination. 


However, it all came to a head when I wanted to try a new print developer and use it with a tray so I could monitor when the first signs of the image appeared, then transfer it to the processor for stop and fix. I should explain that the darkroom does not have running water. I usually part fill a tray with water to put the fixed photographs in then wash them at the end of the session in the bathroom. Anyway I had the water tray precariously balanced on top of the slot covers in their tray as the rest of the top was taken up with the developing tray. It must have been a good day as I did not manage to tip the whole lot over myself. 

I now seriously considered ways of storing the slot tops that would keep the worktop clear. It came to me that the best way was to stand them on end. My first thought was to use a number of metal clips attached to the wall. I cannot understand why I had not come to this conclusion sooner. Once I had thought about it. It was not such a good idea as fix attacks metal. I decided it would be better to use plastic, so took some measurements, sat down and did a number of drawings of a tray that would hold the tubes upright. Then thought about how to stop cross contamination, so added sections to the base. Once I had refined the basic look and measurements I showed the idea to my mate at Plasweld, he helped to simplify the design and added a splash back to stop chemicals running all over the place when loading the tops into the stand. 



A few weeks later the stand is finished. It works very well and has freed up lots of space on the worktop allowing me to work more safely. Such a simple idea that has made a big difference.



A typical layout for a darkroom